Rice-lake Counterpart Configurable Counting Indicator - User Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Váhy Rice-lake Counterpart Configurable Counting Indicator - User. Rice Lake Counterpart Configurable Counting Indicator - User Manual - Version 1.0 User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 87
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
118677
Counterpart
Counting Scale Indicator
Version 1.0
User Manual
To be the best by every measure
®
Zobrazit stránku 0
1 2 3 4 5 6 ... 86 87

Shrnutí obsahu

Strany 1 - User Manual

118677CounterpartCounting Scale IndicatorVersion 1.0User ManualTo be the best by every measure®

Strany 2

4 Counterpart User ManualFigure 1-1. Numeric Keypad1.5 Tare RecallWhen a stored tare is displayed, Net annunciators will be turned on. To display a st

Strany 3 - Contents

Counterpart User Manual - Introduction 51.9 Indicator OperationsBasic Counterpart operations are summarized below.Toggle Gross/NetPress the GROSS/NET

Strany 4

6 Counterpart User Manual2.0 InstallationCounterpart is available in different configurations from just the indicator display to the display and count

Strany 5

Counterpart User Manual - Installation 72.2 LevelingSelect a location for the Counterpart that is reasonably level and free of vibrations and air curr

Strany 6

8 Counterpart User Manual2.7 Cable GroundingExcept for the power cord, all cables should be grounded against the scale enclosure. Do the following to

Strany 7 - About This Manual

Counterpart User Manual - Installation 92.7.3 Network Connection to CounterpartCounterpart has an onboard Ethernet connection. It’s wireless connectiv

Strany 8 - 1.0 Introduction

10 Counterpart User ManualFigure 2-3. Counterpart CPU BoardIf the RESET button on the CPU board is pressed, the scale will perform a reboot.Jumper Des

Strany 9 - 1.4 Keypad Functions

Counterpart User Manual - Installation 112.12 Indicator Replacement Parts and Assembly DrawingsFigure 2-4. Counterpart Indicator Replacement PartsRef

Strany 10 - 1.7 Softkey Setup

12 Counterpart User ManualFigure 2-5. Counterpart Front View

Strany 11 - 1.9 Indicator Operations

Counterpart User Manual - Installation 13Figure 2-6. Counterpart Assembly and Components

Strany 13 - W arning

14 Counterpart User ManualFigure 2-7. Counterpart DimensionsFigure 2-8. Counterpart Rear and Side Dimensions

Strany 14 - 2.7 Cable Grounding

Counterpart User Manual - Configuration 153.0 Configuration3.1 Front Panel ConfigurationTo set up and configure the Counterpart counting Scale, you wi

Strany 15 - 2.11 Installing Option Cards

16 Counterpart User ManualVarious keys are used as directional keys to navigate through the menus (see Figure 3-2). The SAMPLE ( ) and PRINT ( ) keys

Strany 16 - PC1 Jumper

Counterpart User Manual - Configuration 173.4 Audit MenuThe audit menu accesses audit trail support. It provides tracking information for configuratio

Strany 17

18 Counterpart User Manual3.5 Menu Structures and Parameter DescriptionsThe Counterpart scale can be configured using a series of menus accessed throu

Strany 18 - 12 Counterpart User Manual

Counterpart User Manual - Configuration 19Figure 3-6. Setup Menu: Scale SubmenuFEATUR PFORMTSERIAL DIGIOXXXXXXXIDDISPLAYTESTSETUPAUDIT CALIBRSCALESFOR

Strany 19

20 Counterpart User ManualSETUP MenuParameter Choices DescriptionLevel 3 submenuSCALES 1 AND 2 Allows configuration and calibration of each scaleLevel

Strany 20 - 14 Counterpart User Manual

Counterpart User Manual - Configuration 21DFSENS 4OUT2OUT8OUT16OUT32OUT64OUT128OUTDigital filter cutout sensitivity. Specifies the number of consecuti

Strany 21 - 3.2 Menu Navigation

22 Counterpart User ManualLevel 5 submenus - FormatPRIMRY UNITSDECPNTDSPDIVAllows you to set the primary units, decimal point format, and display divi

Strany 22 - 3.3 Revolution Configuration

Counterpart User Manual - Configuration 233.6.2 SCALE 3 SubmenuFigure 3-7. Scale 3 Serial MenuSCALE 3 SubmenuParameter Choices DescriptionFormat Subm

Strany 23 - 3.4 Audit Menu

Contents1.0 Introduction...

Strany 24 - 3.6 Setup Menu

24 Counterpart User Manual3.6.3 FEATUR SubmenuFigure 3-8. FEATUR Submenu NEGCOUNTSAMPLQTY LOTUPDT1ONOFFCOUNTREGIONUIDCONSC#PASSWDSOFTKEYSKEYLCK1025SCA

Strany 25 - Scale Parameter Levels

Counterpart User Manual - Configuration 25 FEATUR MenuParameter Choices DescriptionLevel 3 submenus - FeatureCOUNT NEGCOUNTSAMPLEQTYINSFSMPLLOTUPDTSCL

Strany 26 - SETUP Menu

26 Counterpart User ManualRECALL ONOFFON allows the Tare, Zero, and Units values to be maintained across a power cycle. Over/Under/Target/ID values ar

Strany 27

Counterpart User Manual - Configuration 27DISPMODE CountWeighUnit WeightDisplay mode. This chooses the value to be displayed as large in viewing windo

Strany 28

28 Counterpart User ManualSK1-12 BLANKTIMEDATECLR TARDSPTARDSP ACCSCL SELCODELOTPRINT PLTSWAP DSPINOUTCLR CNTOTAL +TOTAL -CLR TTLLabels softkeys for a

Strany 29 - 3.6.2 SCALE 3 Submenu

Counterpart User Manual - Configuration 293.6.4 FEATUR Menu, REGULA / INDUST SubmenuFigure 3-9. FEATUR Menu, REGULA/INDUST SubmenuDFORMT MMDDY4DDMMY4Y

Strany 30 - Figure 3-8. FEATUR Submenu

30 Counterpart User ManualKTARE YES NOAlways allow keyed tare.MTARE REPLACREMOVENOTHINMultiple tare action.NTARE NOYESAllow negative or zero tare.CTAR

Strany 31 - UNITWTUPDATE

Counterpart User Manual - Configuration 313.6.5 Serial, PFORMT, DIG I/O, VERS SubmenusFigure 3-10. Serial, PFORMT, DIG I/O, VERS SubmenusSCALES FEATUR

Strany 32 - FEATUR Menu

32 Counterpart User ManualSETUP MenuParameter Choices DescriptionLevel 2 submenusSCALE See Section 3.6.1 on page 18 Configure scale settings. See the

Strany 33

Counterpart User Manual - Configuration 33Level 3 submenus - Under the Level 2 Version FeatureSOFTWR V1.XX Displays the software versionREG LR, V 1.XX

Strany 34

ii Counterpart User Manual4.1 Front Panel Calibration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strany 35

34 Counterpart User ManualIND SCALE BAUDBITSSTOP BITSTERMINEOLDYSFMTSets up the transmission information for the industrial scale parameter.SETUP Menu

Strany 36

Counterpart User Manual - Configuration 353.7 Calibration MenuSee Section 4.0 on page 39 for calibration procedures. The Calibration menu can be prote

Strany 37 - COMING SOON

36 Counterpart User Manual3.8 Test MenuFigure 3-12. Test MenuTEST MenuParameter Choices DescriptionLevel 2 submenusA/D AD1AD2EXCVACGives details of cu

Strany 38 - WEIGHVAULT

Counterpart User Manual - Configuration 373.9 Display MenuThere are three display settings on the Counterpart. Figure 3-13. DISPLAY MenuSetting the di

Strany 39

38 Counterpart User Manual3.10 ID MenuThe ID menu displays parameters for registers from 1 to 150. Sub-parameters are shown below.Figure 3-14. ID Menu

Strany 40

Counterpart User Manual - Calibration 394.0 CalibrationThe Counterpart can be calibrated using the front panel, EDP commands, or Revolution®. Calibrat

Strany 41 - 3.7 Calibration Menu

40 Counterpart User ManualFive-point linearization - COMING SOON Rezero - COMING SOON4.2 EDP Command CalibrationTo calibrate the indicator using EDP c

Strany 42

Counterpart User Manual - Calibration 414.4 More About CalibrationThe following topics provide additional information about compensating for environme

Strany 43 - 3.9 Display Menu

42 Counterpart User Manual5.0 Scale OperationsThe following paragraphs contain detailed operator instructions for Counterpart. Included are instructio

Strany 44 - 3.10 ID Menu

Counterpart User Manual - Scale Operations 435.3 Toggling Between Gross and NetTo toggle between net and gross weight, a tare value must be entered in

Strany 45 - 4.0 Calibration

9.5 Custom Stream Formatting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 689.6 D

Strany 46 - Figure 4-2. Scale Button

44 Counterpart User Manual5.4.1 Unit Weight Operation by SamplingUnit weight operation by sampling is accomplished by placing a 10 piece sample on the

Strany 47 - 4.4 More About Calibration

Counterpart User Manual - Scale Operations 45Counting Out of a Full Container - See Total Amount Remaining in the ContainerTo carry out this operation

Strany 48 - 5.0 Scale Operations

46 Counterpart User Manual4. When you have reached the REG number you want to set, press to select that register number.5. Press and enter the COD

Strany 49 - 5.4 Entering Unit Weights

Counterpart User Manual - Scale Operations 475.5.3 Adding an ID From Count Mode1. Press the CODE softkey.2. Add in the ID number.3. If the ID number i

Strany 50

48 Counterpart User Manual5.5.5 WeighVaultWeighVault is a PC program which allows Counterpart users to add, edit, and access IDs over a network connec

Strany 51 - Figure 5-1. ID Menu

Counterpart User Manual - Scale Operations 495.6 Totalization CountsCounterpart has a totalization function that allows you to totalize the quantity o

Strany 52

50 Counterpart User Manual5.8 Connecting a Barcode ScannerThe Counterpart will accept a barcode scanner connected to the unit. In order to use a scann

Strany 53

Counterpart User Manual - Serial Commands 516.0 Serial CommandsThe Counterpart can be controlled by a PC or remote keyboard connected to an indicator

Strany 54

52 Counterpart User Manual6.1.2 Keypad LockThe user has the ability to lock or unlock the keypad. The commands are listed in Table 6-2.6.1.3 ID Comman

Strany 55 - 5.7 Parts Reduction Counts

Counterpart User Manual - Serial Commands 536.1.5 Reporting CommandsReporting commands send specific information to the serial port. The commands list

Strany 56 - Unit Weight 1

iv Counterpart User Manual

Strany 57 - 6.0 Serial Commands

54 Counterpart User ManualCommand Description ValuesSC.GRADS#n Graduations 1–100000SC.ZTRKBND#n Zero track band 0, 0–100SC.ZRANGE#n Zero range 1.90000

Strany 58 - Table 6-4 can be used

Counterpart User Manual - Serial Commands 55EDP.ECHO#p Port echo ON, OFFEDP.EOLDLY#p Port end-of-line delay 0–255 (0.1-second intervals)EDP.HEADERS#p

Strany 59

56 Counterpart User ManualREG.BASE Zero base for overload calculation CALIB, SCALE REG.PRTMOT Allow print while in motion NO, YESREG.PRINTPT Add PT to

Strany 60

Counterpart User Manual - Serial Commands 576.1.8 Normal Mode CommandsThe normal mode print commands (see Table 6-12) transmit data to the serial port

Strany 61

58 Counterpart User Manual7.0 Print FormattingThe Counterpart provides eight print formats, GFMT, NFMT, TOTALFMT, PALFMT, CFMT, ACCFMT, HDRFMT1 andHDR

Strany 62

Counterpart User Manual - Print Formatting 59Command DescriptionSupported Ticket Formats<G> Gross weight in displayed unitsGFMT, NFMT, TOTALFMT,

Strany 63 - Table 6-13. Unique Commands

60 Counterpart User ManualThe 500-character limit of each print format string includes the output field length of the print formatting commands, not t

Strany 64 - 7.0 Print Formatting

Counterpart User Manual - Print Formatting 61The default Counterpart print formats are shown in Table 7-2 and Table 7-3:7.2 Customizing Print FormatsT

Strany 65 - , NFMT

62 Counterpart User ManualFigure 7-1. PFORMT Menu, Showing Alphanumeric Character Entry Procedure7.2.3 Using Revolution® The Revolution configuration

Strany 66

Counterpart User Manual - Print Formatting 637.2.4 Print Label ExamplesListed below are print formatting examples that appear with the various formats

Strany 67 - 7.2 Customizing Print Formats

Counterpart User Manual - 1About This ManualThis manual is provided for the use of trained and qualified installers of counting scales, and represent

Strany 68 - 62 Counterpart User Manual

64 Counterpart User ManualTotal Label FormatFigure 7-6. Total Format Label ExampleGross/Tare/Net Label FormatFigure 7-7. Gross/Tare/Net Label Format

Strany 69

Counterpart User Manual - WLAN Installation Instructions 658.0 WLAN Installation InstructionsBefore installing this option, you must contact your IT a

Strany 70 - Gross/Tare/Net Label Format

66 Counterpart User Manual9.0 Appendix9.1 Error MessagesIf an error code appears on the display, use the information in Table 9-1 as a troubleshooting

Strany 71

Counterpart User Manual - For More Information 67Table 9-2. Error Codes Returned on XE Command9.2.1 Using the P EDP CommandThe P EDP command returns t

Strany 72 - - - - - -

68 Counterpart User Manual9.3 Continuous Output (Stream) FormatFigure 9-1 shows the continuous output format sent to a Counterpart port when that port

Strany 73 - 9.2.1 Using the P EDP Command

Counterpart User Manual - For More Information 69<M[G | N | T]> STR.GROSSSTR.NETSTR.TAREMode. Specifies gross, net, or tare weight for the curre

Strany 74 - 9.5 Custom Stream Formatting

70 Counterpart User ManualB17 Configuration =000 if current DECPNT=8888800=001 if current DECPNT=8888880=010 if current DECPNT=8888888=011 if current

Strany 75

Counterpart User Manual - For More Information 719.6 Digital FilteringThe Counterpart uses averaged digital filtering to reduce the effect of vibratio

Strany 76

72 Counterpart User Manual9.6.3 Setting the Digital Filter ParametersFine-tuning the digital filter parameters greatly improves indicator performance

Strany 77 - 9.6 Digital Filtering

Counterpart User Manual - For More Information 739.7 Serial Scale InterfaceSerial port 1 can be configured for serial scale input. The serial scale fu

Strany 78 - 9.6.4 Audit Trail Support

2 Counterpart User Manual1.0 IntroductionThe Counterpart offers practical solutions for a full range of precision counting applications. A bright LCD

Strany 79 - 9.7 Serial Scale Interface

74 Counterpart User Manual9.8 Regulatory Mode FunctionsThe function of the front panel TARE and ZERO keys depends on the value specified for the REGUL

Strany 80 - 9.8 Regulatory Mode Functions

Counterpart User Manual - For More Information 759.9 Updating FirmwareTo update firmware of the Counterpart, you must have Revolution installed and a

Strany 81 - 9.9 Updating Firmware

76 Counterpart User ManualFigure 9-5. Rice Lake Updater Screen8. Click the Program button. The update will take several moments. 9. When complete, rem

Strany 82 - 9.10 Specifications

Counterpart User Manual - For More Information 779.11 SpecificationsPOWER:Power source:Input: 100-240VAC, 47-63 Hz, 5 watts, US power cordOutpu

Strany 83 - 9.11 Specifications

78 Counterpart User ManualCounterpart Limited WarrantyRice Lake Weighing Systems (RLWS) warrants that all RLWS equipment and systems properly installe

Strany 84 - Counterpart Limited Warranty

Counterpart User Manual - For More Information 79For More InformationLiterature• Counterpart Sales Literature, PN 125545• Counterpart CD with WeighVau

Strany 86

PN 118677 06/11

Strany 87 - PN 118677 06/11

Counterpart User Manual - Introduction 31.4 Keypad Functions Key Function POWERTurns the Counterpart unit on/off.NOTE: If the PC1 jumper is set

Komentáře k této Příručce

Žádné komentáře