22
Customizing Print Format (Optional)
Ø Press [
G/N
] key and [
Select/Enter
] key together, Audit Trail will be displayed,
when released the display will show [
P 0
] and the 7
th
LED will flash, which
means you need to enter the numeric value password to access the setup mode.
Ø Key in the password [
2
] [
0
] [
0
] [
1
] and press [
Enter
], the display will show [
C1
]
Ø Press [Shift] then [0], [PRT FMT] will be displayed, then [P1 CUST] will be
displayed.
Here you can use the [
PRINT
] key or [
G/N
] key to browse the following three menus,
(1) [
P1 CUST
] Ø For Custom Print Formatting.
(2) [
P2 CONT
] Ø For Custom Formatting for Continuous Output.
(3) [
FMT END
] Ø to end the Custom Formatting and return to normal weighing mode.
select the menu by pressing the Enter key and continue the setting.
Ø The numeric characters (0, 1, … , 9), all alphabets (A, B, … , Z) and some other
characters are already assigned to the Group-B keys (Ref: Key Explanation page as
describe earlier) so these characters can be keyed in directly from Group-B keys.
(Example: for “1” Ø press [
1
] key,
for “A” Ø press [
Shift
] then press [
2
] key,
for “B” Ø press [
Shift
] then press [
2
] and press [
Shift
] key.
To confirm character entry, press [
Enter
] key after selecting the input
character).
q
There will be a blinking LED just below one of the 7-segment display digits
which shows the active digit position or character insertion position.
Ø The characters or text to be printed out should be place d inside the double
quotation marks.
(e.g. “FlexWeigh” will print out as FlexWeigh )
Ø For Control characters or some other characters which cannot be used by the
front panel keys are to be keyed in by using the following format:
“
\xxx
” (where:
xxx
is the ASCII code or extended ASCII code (0~255) in
decimal value of the character code to be printed)
Ø
Following Command Codes are provided
:
(1) “
\R
” = Carriage Return
(2) “
\N
” = Line Feed
(3) “
\E
” = End of line (CR+LF) (e.g. “\E” = “\R\N” will be printed)
(4) “
\Lx
” = “x” Line Feeds (e.g. “\L3” = “\N\N\N” = 3 Line Feeds will be printed)
(5) “\Sx” = “x” Spaces (e.g. “\S4” = 4 spaces will be printed)
(6) “
\CX.Y
” = Repeat printing a character X for a total of Y characters, X can be
“\xxx” form (e.g. “\C=.16” = Prints “=” for 16 characters or “\C\42.16 = Prints “*”
for 16 characters)
Ø
Weight Format Command (WX.Y)
X = Weight Type (0 = Net, 1 = Gross, 2 = Tare)
Y
= Field Width (Includes “.” if any)
Ø Weight Unit Command (U)
Appends the current unit of measurement to the printed weight and optional tare
entry flag.
(1) “^kg^^^” For Pushbutton Tare, Gross or Net Weight. (kg = current unit, ^
= space)
(2) “^kg(K)” For Keyboard Tare or Recall Tare Weight.