Journal Print Format & Printout Sample
Journal Print Format is enabled by the settings: 1) Custom Print Format Type (
C3.6
“PFM” = CPR) with the proper Journal Print Format in C10.1 as will be described
below, 2) Date/Time Setup Enable (
C1.4
“DTM” = E) and 3) Journal Print Feature
Enable (
C1.5
“JPR” = E) .
Following commands are specially provided for Journal Pri nter Print Formats:
Ø
Journal Print Format Commands (FX)
Where X = Format No. 1 to 5.
Each of the following command defines the format header or a start position of
print format.
F1
= Start of Main Title Format
F2
= Start of Sub Title Format
F3
= Start of Batch Weighing Format
F4
= Start of Sub Total Format
F5
= Start of Grand Total Format
Note
: At the end of each format, “CR/LF” pair will be printed, except at the end of
F5
.
Ø
Code and Number Format Commands (NX)
Where X = Format No. 1 to 4.
Each of the following command represents the Code or Numeric Data to be printed.
N1
= Product Code (10 Alpha-Numeric Characters)
N2
= Consecutive No. (5 Numeric Characters)
N3
= Sub Total Counts (5 Numeric Characters)
N4
= Grand Total Counts (5 Numeric Characters)
Ø
Weight and Unit Format Commands (WX.Y.U)
X = Weight Type (0 = Net, 1 = Gross, 2 = Tare,
3
= Sub Total Weight,
4
= Grand Total Weight).
Y
= Field Width (Includes “.” if any)
U
= Appends the current unit of measurement to the weight and optional tare entry
flag.
(1)
U
=
0
: Not print current unit of measurement. (Same as W.X.Y)
(2) U = 1: Appends the current unit of measurement (“^kg”) to the printed weight.
(3)
U
=
2
: Appends as described in (2) but with 3 additional characters of tare
entry flag:
(a) “^^^” For Pushbutton Tare, Gross or Net We ight (^ = Space).
(b) “(K)” For Keyboard Tare or Recall Tare Weight.
q
Example:
Following will print the net weight right justified with a field width of
8 and will finally print a different type of optional current unit of measurement
description:
W0.8.0
=
without current unit: e.g.
“ 3456.78”
(same as W0.8).
W0.8.1
= 1 space and 2 characters of current unit: e.g.
“ 3456.78 kg”.
W0.8.2
= 1 space and 2 characters of current unit with 3 extra spaces of tare
flag. e.g.
“ 3456.78 kg ”
(same as W.0.8U).
Ø
Time Format Commands (TX)
Where X = Time Format No. 1 to 8 as follows:
Command
Format Print Out
T1 H:MM 2:13
T2 HH:MM 02:13
T3 H:MM AM/PM 2:13 AM
T4 HH:MM: AM/PM 02:13 AM
T5 H:MM:SS 2:13:00
T6 HH:MM:SS 02:13:00
T7 H:MM:SS AM/PM 2:13:00 AM
T8 HH:MM:SS AM/PM 02:13:00 AM