78 880 Technical/Service Manual
7.2 Default Print Formats
Table 7-2 shows the default print formats for the 880 and lists the conditions under which each print format is used.
The
HDRFMT format is used to specify header information that can be used by the other print formats. The contents
of the
HDRFMT format can be inserted into any other print format using the <H1> formatting command.
Table 7-2. Default Print Formats
Format Default Format String Used When
GFMT | FMT GROSS<G><NL2><TD><NL> Normal mode, no tare in system
GFMT | PORT Defines the communication port that the format wi
ll be sent to.
NFMT | FMT GROSS<G><NL>TARE<SP><T><NL>NET
<SP2><N><NL2><TD><NL>
Normal mode, tare in system
NFMT | PORT Defines the communication port that the format wi
ll be sent to.
ACCFMT | FMT ACCUM<A><NL><DA> <TI><NL> Accumulator enabled and displayed, or
setpoint print operation
with PSHACCM=ON
ACCFMT | PORT Defines the communication port that the format wi
ll be sent to.
SPFMT | FMT <SCV><SP><SPM><NL> Setpoint push print operation (PSHPRNT=ON or WAITSS)
SPFMT | PORT Defines the communication port that the format wi
ll be sent to.
Note
In OIML and CANADA modes, the letters PT (preset tare) are automatically inserted after the printed tare
weight.
If the COM port is set to TYPE = RS485, the port
will not perform a demand print. See Section 10.6.3.
<CR> Carriage return character
<LF> Line feed character
Note
1. Gross, net, and tare weights are 8 digits in length, including sign and decimal point, followed by a space and a one-
to five-digit units identifier. Total field length with units identifier is 10-14 characters. Depending on what units are
configured, the units identifier will be lb, kg, oz, tn, t, or g.
2. Gross, net, tare, and accumulator weights can be printed in any
configured weight units by adding the following
modifiers to the gross, net, tare, and accumulator weight commands: /P (primary units), /D (displayed units), /S
(secondary units), /T (tertiary units). If not specified, the current displayed units (/D) is assumed. Example: To format
a ticket to show net weight in secondary units, use the following command: <N/S>.
3. Unit ID and consecutive number (CN) fields are 1–6 characters in length, as required.
4. If nn is not specified, 1 is assumed. Value must be in the range 1–99.
5. After receiving an SU command, the indicator sends unformatted data
until the next SU command is received.
Unformatted data omits decimal points, leading and trailing characters.
Command Description
Ticket Format
GFMT/NFMT/
ACCFMT
SPFMT
Table 7-1. Print Format Commands (Continued)